{"id":7048,"date":"2026-09-16T09:00:00","date_gmt":"2026-09-16T01:00:00","guid":{"rendered":"https:\/\/belirollforming.com\/sdi-standard-roll-forming-tolerances\/"},"modified":"2026-10-13T10:49:02","modified_gmt":"2026-10-13T02:49:02","slug":"sdi-standard-roll-forming-tolerances","status":"publish","type":"post","link":"https:\/\/belirollforming.com\/ru\/sdi-standard-roll-forming-tolerances\/","title":{"rendered":"SDI Standard: 6 Roll Forming Dimensional Tolerances You Must Meet"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"7048\" class=\"elementor elementor-7048 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-b43d9fc elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"b43d9fc\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-65bcb3c\" data-id=\"65bcb3c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c661b30 elementor-widget elementor-widget-text-editor\" data-id=\"c661b30\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p># SDI Standard: 6 Roll Forming Dimensional Tolerances You Must Meet<\/p>\n\n<h2>Metadata<\/h2>\n\n<p><strong>Title options:<\/strong><\/p>\n<ol>\n  <li>SDI Standard: 6 Roll Forming Dimensional Tolerances You Must Meet<\/li>\n  <li>SDI Standard: 6 Proven Deck Tolerances for Roll Forming<\/li>\n  <li>SDI 2019: 6 Dimensional Tolerances Every Deck Must Hold<\/li>\n<\/ol>\n<p><strong>Meta descriptions:<\/strong><\/p>\n<ol>\n  <li>The SDI standard sets 6 roll forming dimensional tolerances for steel deck: sweep, camber, web flatness, lip height and more. Miss them and field fit-up fails.<\/li>\n  <li>What does the SDI standard require of roll formed deck? See 6 dimensional tolerances with the numbers specifiers enforce.<\/li>\n  <li>SDI standard roll forming tolerances: 6 key limits on sweep, camber and flatness that decide whether your deck fits on site.<\/li>\n<\/ol>\n<p><strong>URL slug:<\/strong> sdi-standard-roll-forming-tolerances<\/p>\n<p><strong>Categories:<\/strong> Compliance &amp; Standards, Technology<\/p>\n<p><strong>Tags:<\/strong> SDI standard roll forming tolerances, steel deck dimensional tolerance, SDI 2019, roll formed deck flatness, deck sweep tolerance, deck camber, roll forming accuracy, Beli Rollforming, Believe Industry<\/p>\n\n<h2>What the SDI Standard Actually Controls<\/h2>\n\n<p>The <a href=\"https:\/\/www.sdi.org\/\" target=\"_blank\" rel=\"noopener noreferrer\">Steel Deck Institute (SDI)<\/a> writes the standard most North American engineers cite for steel floor deck. The current edition is SDI 2019. It defines how a composite deck must look and measure after roll forming, on a material basis of galvanized steel made to <a href=\"https:\/\/www.astm.org\/\" target=\"_blank\" rel=\"noopener noreferrer\">ASTM A653<\/a>.<\/p>\n<p>The <a href=\"https:\/\/www.steel.org\/\" target=\"_blank\" rel=\"noopener noreferrer\">American Iron and Steel Institute (AISI)<\/a> covers the cold formed steel design side, while <a href=\"https:\/\/www.astm.org\/\" target=\"_blank\" rel=\"noopener noreferrer\">ASTM International<\/a> supplies the test methods that prove a coil meets spec before it reaches the roll former. A deck can use perfect ASTM A653 steel and still fail if the profile is bent, so the standard lists dimensional tolerances the machine must hold on every meter of output.<\/p>\n<table>\n  <tr><th>Tolerance<\/th><th>SDI 2019 limit<\/th><th>Why it matters<\/th><th>How the machine controls it<\/th><\/tr>\n  <tr><td>Sweep<\/td><td>3 to 6 mm per 3 m<\/td><td>Deck will not sit parallel to beams<\/td><td>Aligned roll stations, straight side rails<\/td><\/tr>\n  <tr><td>Camber<\/td><td>1 to 3 mm<\/td><td>Panel bows across the bay<\/td><td>Equal side thrust, symmetric setup<\/td><\/tr>\n  <tr><td>Web flatness<\/td><td>\u00b11.5 mm<\/td><td>Concrete contact, stud weld<\/td><td>Crowned rolls, tension control<\/td><\/tr>\n  <tr><td>Lip height \/ shape<\/td><td>\u00b11.0 mm<\/td><td>Side lap seal and handling<\/td><td>Finishing pass calibration<\/td><\/tr>\n  <tr><td>End squareness<\/td><td>\u00b11.5 mm<\/td><td>Butt joint alignment<\/td><td>Servo tracking cut index<\/td><\/tr>\n  <tr><td>Profile depth<\/td><td>\u00b11.5 mm<\/td><td>Fire rating, composite action<\/td><td>Roller gap set to nominal depth<\/td><\/tr>\n<\/table>\n\n<h2>Sweep and Camber: The Two That Break Field Fit-Up<\/h2>\n\n<p>Sweep is the side-to-side bow along the length of the deck. The SDI standard allows 3 to 6 mm of sweep per 3 m of panel, depending on the deck width class. A deck that sweeps too far will not run parallel to the supporting beam. Erection crews then have to force it, which opens gaps at the side lap and invites callbacks.<\/p>\n<p>Camber is the vertical bow, a gentle arch across the panel length. The standard limit is 1 to 3 mm. Two panels with opposite camber will not butt cleanly at a construction joint, and the slab thickness becomes uneven where it matters most.<\/p>\n<p>Both defects trace back to the same root cause: asymmetry in the forming line. If one side of the profile is drawn tighter than the other, the strip curls. That is why roll station alignment is the first thing a good commissioning engineer checks before the first coil runs.<\/p>\n<p>When you audit a supplier, ask for a sweep and camber report on a full production coil, not a hand picked sample. The <a href=\"https:\/\/belirollforming.com\/metal-floor-deck-roll-forming-machine-buying-guide\/\" target=\"_blank\" rel=\"noopener noreferrer\">metal floor deck roll forming machine buying guide<\/a> shows the test method we recommend. A line that holds 3 to 6 mm sweep and 1 to 3 mm camber on every coil is a line you can ship with confidence.<\/p>\n\n<h2>Web Flatness, Lip Height and Profile Depth<\/h2>\n\n<p>Web flatness is the flatness of the wide horizontal surface that receives the concrete. The SDI standard allows \u00b11.5 mm deviation across the web. If the web waves or oil cans, the welded shear studs sit proud of the surface and the thin concrete cover over them drops below the fire rating.<\/p>\n<p>Lip height and lip shape carry a \u00b11.0 mm tolerance. The lip is the small upturned edge that locks adjacent panels at the side lap. If the lip is too short the lap leaks grout. If it is too tall the next panel will not seat. Lip shape matters as much as height, so the tolerance covers both.<\/p>\n<p>Profile depth is the overall rib height, held to \u00b11.5 mm in SDI 2019. Depth sets the slab&#8217;s neutral axis and therefore the composite strength the engineer stamped on the drawings. The roller gap and the final pass set this dimension, which is why <a href=\"https:\/\/belirollforming.com\/roll-forming-roller-materials-7-steel-grades-compared\/\" target=\"_blank\" rel=\"noopener noreferrer\">roll forming roller materials<\/a> matter: harder rolls hold depth longer.<\/p>\n<table>\n  <tr><th>Parameter<\/th><th>SDI 2019 value<\/th><th>Failure symptom on site<\/th><\/tr>\n  <tr><td>Web flatness<\/td><td>\u00b11.5 mm<\/td><td>Wavy slab, proud studs<\/td><\/tr>\n  <tr><td>Lip height<\/td><td>\u00b11.0 mm<\/td><td>Grout leak or open side lap<\/td><\/tr>\n  <tr><td>Profile depth<\/td><td>\u00b11.5 mm<\/td><td>Lost composite strength<\/td><\/tr>\n  <tr><td>Overlap width<\/td><td>Per profile<\/td><td>Misaligned side joint<\/td><\/tr>\n<\/table>\n\n<h2>End Squareness and Cut Length Accuracy<\/h2>\n\n<p>End squareness is the angle of the cut end relative to the deck length. The SDI standard expects the end to be square within \u00b11.5 mm across the panel width. A ragged end means two panels cannot butt at a construction joint without a shim. That single defect can stop a whole pour.<\/p>\n<p>Cut length accuracy is where the roll forming machine earns its keep. A servo tracking flying cut should hold \u00b10.5 mm at full line speed. That tolerance lets the erector stack panels end to end without trimming on site. A stop and cut shear is cheaper but slower and less repeatable, which is why high volume deck lines pay for servo tracking.<\/p>\n<p>Squareness and length are controlled at the cutoff, not the rolls. The deck must be held firmly and tracked true as it enters the shear. If the strip drifts, the cut walks and every panel after it inherits the error. Good lines use a measuring encoder and a tracking gate that follows the motion. The <a href=\"https:\/\/belirollforming.com\/floor-deck-profile-6-types-dovetail-deep-rib\/\" target=\"_blank\" rel=\"noopener noreferrer\">floor deck profile types guide<\/a> explains how dovetail and deep rib profiles change the cut layout. Always tie the acceptance test to a measured production coil, never to a single perfect offcut.<\/p>\n\n<h2>How the Roll Forming Machine Holds These Tolerances<\/h2>\n\n<p>Roll station alignment is the foundation of every tolerance above. Each station must sit on a straight, parallel centerline so the strip is bent progressively and symmetrically. A station that is 0.2 mm off axis adds a little sweep, and twenty stations later the panel misses the SDI limit. Alignment is checked at commissioning.<\/p>\n<p>Servo tracking cut is the second pillar. It keeps the strip moving while the shear follows it, then snaps the cut at the exact commanded length. This is what delivers \u00b10.5 mm cut length and \u00b11.5 mm end squareness at speed. Without it, the line must stop to cut and length drift creeps in between stops.<\/p>\n<p>Roll material and finish protect the tolerances over time. Hardened D2 or Cr12MoV rolls resist the brinelling and polishing that let a profile drift out of spec after a few thousand tons. The <a href=\"https:\/\/belirollforming.com\/roll-forming-roller-materials-7-steel-grades-compared\/\" target=\"_blank\" rel=\"noopener noreferrer\">roller materials comparison<\/a> covers the trade offs in detail.<\/p>\n<p>Tension and strip guiding stop the web from waving. A well set decoiler and entry guide keep the coil centered so both lips form evenly. Combined with correct pass design, this holds web flatness to \u00b11.5 mm and lip height to \u00b11.0 mm. A line built for deck from the start holds these numbers better than one adapted from a purlin profile.<\/p>\n<table>\n  <tr><th>Machine control<\/th><th>Tolerance protected<\/th><th>Typical machine spec<\/th><\/tr>\n  <tr><td>Roll station alignment<\/td><td>Sweep, camber<\/td><td>\u00b10.1 mm per station<\/td><\/tr>\n  <tr><td>Servo tracking cut<\/td><td>End squareness, cut length<\/td><td>\u00b10.5 mm length<\/td><\/tr>\n  <tr><td>Hardened roller set<\/td><td>Lip height, depth<\/td><td>Holds to 1,000 t<\/td><\/tr>\n  <tr><td>Strip guide and tension<\/td><td>Web flatness<\/td><td>\u00b11.5 mm web<\/td><\/tr>\n<\/table>\n\n<h2>Why Tolerances Protect Welded Shear Studs<\/h2>\n\n<p>Welded shear studs are what turn a steel deck into composite deck. The studs are shot welded through the web to the beam below, then buried in the concrete. If the web is not flat within \u00b11.5 mm, the stud gun cannot seat the stud square to the surface. A tilted stud loses weld area and the composite connection weakens.<\/p>\n<p>The SDI standard exists because a deck that looks fine can still fail the field. A wavy web gives proud studs and thin cover. A bad lip gives a leaking side lap that stains the ceiling below. A missing square end stops the pour. None of these show up in a tensile test, but all of them show up as claims and delays.<\/p>\n<p>Specifiers tie the deck to the fire rating through slab thickness and cover. The profile depth tolerance of \u00b11.5 mm protects that rating. If the rib is shallow, the concrete over the stud drops below the required cover and the authority having jurisdiction can fail the inspection. Tolerances are therefore a safety control, not a cosmetic one.<\/p>\n<p>This is why <a href=\"https:\/\/belirollforming.com\/floor-deck-fire-compliance-ul-astm-standards\/\" target=\"_blank\" rel=\"noopener noreferrer\">floor deck fire compliance<\/a> and the SDI dimensional limits belong in the same conversation. A deck that meets one and misses the other is not a compliant deck. Buy the line that holds both, and document it with every coil.<\/p>\n\n<h2>Writing SDI Tolerances Into Your Purchase Contract<\/h2>\n\n<p>A tolerance you cannot measure is a tolerance you cannot enforce. The first clause in any deck line contract should name the edition: SDI 2019, with the material basis ASTM A653 galvanized steel. State that acceptance is by full production coil, not by selected sample, so the supplier cannot cherry pick the best offcut.<\/p>\n<p>Write each of the six limits as a pass or fail line. Sweep 3 to 6 mm per 3 m. Camber 1 to 3 mm. Web flatness \u00b11.5 mm. Lip height \u00b11.0 mm. End squareness \u00b11.5 mm. Profile depth \u00b11.5 mm. Add cut length \u00b10.5 mm from the servo tracking cut. Put the numbers in the contract so there is no room for a friendly reinterpretation later.<\/p>\n<p>Define the test method next to the numbers. Say who measures, with what tool, and on how many panels per coil. A laser trammel for sweep and camber, a flatness gauge for the web, and a square for the end will do. Name the <a href=\"https:\/\/belirollforming.com\/roll-forming-floor-deck-machine-price-5-cost-tiers\/\" target=\"_blank\" rel=\"noopener noreferrer\">cost tier<\/a> of line that delivers the spec so the quotation matches the clause.<\/p>\n<p>Finish with a remedy. State that a coil outside any limit is reworked or replaced at the supplier cost, and that repeated failure triggers a line recommissioning on their time. Buyers who write the SDI standard into the paper get deck that fits the first time.<\/p>\n\n<h2>Conclusion<\/h2>\n\n<p>SDI standard roll forming tolerances turn a coil of ASTM A653 steel into deck a crew can actually erect. The six limits sweep, camber, web flatness, lip height, end squareness and profile depth are what separate a shippable panel from a rejected one. Hold them with aligned roll stations and a servo tracking cut, and write them into the contract before you sign. Do that and your composite deck will seat, weld and pour without a single callback.<\/p>\n\n<h2>FAQ<\/h2>\n\n<p><strong>1. What is the SDI standard for steel deck?<\/strong><\/p>\n<p>The SDI standard is the Steel Deck Institute specification, current as SDI 2019, that sets the dimensional tolerances steel floor deck must hold after roll forming. It defines limits for sweep, camber, web flatness, lip height, end squareness and profile depth so the deck fits and performs on site.<\/p>\n<p><strong>2. What material basis does SDI 2019 use?<\/strong><\/p>\n<p>SDI 2019 assumes the deck is made from galvanized steel produced to ASTM A653, which governs the base metal and coating. The standard itself focuses on shape and dimensions, not chemistry, so the ASTM grade defines the raw material the tolerances are applied to.<\/p>\n<p><strong>3. What is the sweep tolerance for steel deck?<\/strong><\/p>\n<p>The SDI standard allows 3 to 6 mm of sweep per 3 m of panel, depending on deck width class. Sweep is the side to side bow along the length. Too much sweep keeps the deck from running parallel to the supporting beam and opens gaps at the side lap.<\/p>\n<p><strong>4. What is the camber tolerance in SDI 2019?<\/strong><\/p>\n<p>SDI 2019 limits camber to 1 to 3 mm, where camber is the vertical bow across the panel length. Small camber stacks up over long runs and prevents clean butt joints at construction joints, which makes the slab thickness uneven.<\/p>\n<p><strong>5. What is web flatness and why does it matter?<\/strong><\/p>\n<p>Web flatness is how level the wide concrete bearing surface stays, held to \u00b11.5 mm in the SDI standard. A wavy web leaves welded shear studs proud of the surface and reduces concrete cover below the fire rating, so flatness is a safety control as much as a fit up one.<\/p>\n<p><strong>6. What is the lip height tolerance?<\/strong><\/p>\n<p>The SDI standard holds lip height and lip shape to \u00b11.0 mm. The lip locks adjacent panels at the side lap. A short lip leaks grout and a tall lip stops the next panel from seating, so both the height and the form of the lip are checked.<\/p>\n<p><strong>7. How accurate is the cut end of roll formed deck?<\/strong><\/p>\n<p>A servo tracking flying cut holds cut length to \u00b10.5 mm and end squareness to \u00b11.5 mm at full line speed. Squareness within \u00b11.5 mm lets two panels butt cleanly at a construction joint without shims or site trimming.<\/p>\n<p><strong>8. How does the roll forming machine control these tolerances?<\/strong><\/p>\n<p>Aligned roll stations keep sweep and camber in band, while a servo tracking cut controls length and squareness. Hardened roller sets hold lip height and profile depth over time, and strip guiding plus tension keep the web flat within \u00b11.5 mm.<\/p>\n<p><strong>9. Why do tolerances matter for welded shear studs?<\/strong><\/p>\n<p>Welded shear studs shot through the web form the composite connection to the beam below. If the web is not flat within \u00b11.5 mm the stud gun cannot seat the stud square, which cuts weld area and weakens the composite action the engineer designed for.<\/p>\n<p><strong>10. How do I write SDI tolerances into a purchase contract?<\/strong><\/p>\n<p>Name SDI 2019 with the ASTM A653 material basis and state acceptance is by full production coil. List each of the six limits as a pass or fail line, define the test method and tools, and add a remedy for out of tolerance coils. This removes debate at the acceptance test.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fbb74eb elementor-widget elementor-widget-html\" data-id=\"fbb74eb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<script type=\"application\/ld+json\">\n{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the SDI standard for steel deck?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The SDI standard is the Steel Deck Institute specification, current as SDI 2019, that sets the dimensional tolerances steel floor deck must hold after roll forming. It defines limits for sweep, camber, web flatness, lip height, end squareness and profile depth so the deck fits and performs on site.\"}}, {\"@type\": \"Question\", \"name\": \"What material basis does SDI 2019 use?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"SDI 2019 assumes the deck is made from galvanized steel produced to ASTM A653, which governs the base metal and coating. The standard itself focuses on shape and dimensions, not chemistry, so the ASTM grade defines the raw material the tolerances are applied to.\"}}, {\"@type\": \"Question\", \"name\": \"What is the sweep tolerance for steel deck?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The SDI standard allows 3 to 6 mm of sweep per 3 m of panel, depending on deck width class. Sweep is the side to side bow along the length. Too much sweep keeps the deck from running parallel to the supporting beam and opens gaps at the side lap.\"}}, {\"@type\": \"Question\", \"name\": \"What is the camber tolerance in SDI 2019?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"SDI 2019 limits camber to 1 to 3 mm, where camber is the vertical bow across the panel length. Small camber stacks up over long runs and prevents clean butt joints at construction joints, which makes the slab thickness uneven.\"}}, {\"@type\": \"Question\", \"name\": \"What is web flatness and why does it matter?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Web flatness is how level the wide concrete bearing surface stays, held to \u00b11.5 mm in the SDI standard. A wavy web leaves welded shear studs proud of the surface and reduces concrete cover below the fire rating, so flatness is a safety control as much as a fit up one.\"}}, {\"@type\": \"Question\", \"name\": \"What is the lip height tolerance?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The SDI standard holds lip height and lip shape to \u00b11.0 mm. The lip locks adjacent panels at the side lap. A short lip leaks grout and a tall lip stops the next panel from seating, so both the height and the form of the lip are checked.\"}}, {\"@type\": \"Question\", \"name\": \"How accurate is the cut end of roll formed deck?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"A servo tracking flying cut holds cut length to \u00b10.5 mm and end squareness to \u00b11.5 mm at full line speed. Squareness within \u00b11.5 mm lets two panels butt cleanly at a construction joint without shims or site trimming.\"}}, {\"@type\": \"Question\", \"name\": \"How does the roll forming machine control these tolerances?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Aligned roll stations keep sweep and camber in band, while a servo tracking cut controls length and squareness. Hardened roller sets hold lip height and profile depth over time, and strip guiding plus tension keep the web flat within \u00b11.5 mm.\"}}, {\"@type\": \"Question\", \"name\": \"Why do tolerances matter for welded shear studs?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Welded shear studs shot through the web form the composite connection to the beam below. If the web is not flat within \u00b11.5 mm the stud gun cannot seat the stud square, which cuts weld area and weakens the composite action the engineer designed for.\"}}, {\"@type\": \"Question\", \"name\": \"How do I write SDI tolerances into a purchase contract?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Name SDI 2019 with the ASTM A653 material basis and state acceptance is by full production coil. List each of the six limits as a pass or fail line, define the test method and tools, and add a remedy for out of tolerance coils. This removes debate at the acceptance test.\"}}]}\n<\/script>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>The SDI standard sets 6 roll forming dimensional tolerances for steel deck: sweep, camber, web flatness, lip height and more. Miss them and field fit-up fails.<\/p>","protected":false},"author":136317771,"featured_media":7039,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_wpcom_ai_launchpad_first_post":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"{title}\n\n{excerpt}\n\n{url}","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2},"_wpas_customize_per_network":false,"jetpack_post_was_ever_published":false},"categories":[3373,1414],"tags":[1897,3036,3815,3809,3803,3819,3798,3785,3793],"class_list":["post-7048","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-compliance-standards","category-technology","tag-beli-rollforming","tag-believe-industry","tag-deck-camber","tag-deck-sweep-tolerance","tag-roll-formed-deck-flatness","tag-roll-forming-accuracy","tag-sdi-2019","tag-sdi-standard-roll-forming-tolerances","tag-steel-deck-dimensional-tolerance"],"blocksy_meta":[],"jetpack_publicize_connections":[],"jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgM2Nx-1PG","jetpack-related-posts":[],"jetpack_featured_media_url":"https:\/\/belirollforming.com\/wp-content\/uploads\/2026\/10\/325-sdi-tolerances.webp","_links":{"self":[{"href":"https:\/\/belirollforming.com\/ru\/wp-json\/wp\/v2\/posts\/7048","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/belirollforming.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/belirollforming.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/belirollforming.com\/ru\/wp-json\/wp\/v2\/users\/136317771"}],"replies":[{"embeddable":true,"href":"https:\/\/belirollforming.com\/ru\/wp-json\/wp\/v2\/comments?post=7048"}],"version-history":[{"count":1,"href":"https:\/\/belirollforming.com\/ru\/wp-json\/wp\/v2\/posts\/7048\/revisions"}],"predecessor-version":[{"id":7050,"href":"https:\/\/belirollforming.com\/ru\/wp-json\/wp\/v2\/posts\/7048\/revisions\/7050"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/belirollforming.com\/ru\/wp-json\/wp\/v2\/media\/7039"}],"wp:attachment":[{"href":"https:\/\/belirollforming.com\/ru\/wp-json\/wp\/v2\/media?parent=7048"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/belirollforming.com\/ru\/wp-json\/wp\/v2\/categories?post=7048"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/belirollforming.com\/ru\/wp-json\/wp\/v2\/tags?post=7048"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}